Xi'an, Shaanxi, China · OEM / ODM Transformer & Power Supply Manufacturer [email protected]  |  ✔ Intertek-Verified Supplier
OEM & ODM Industrial Power Solutions

Control Transformer Manufacturers & Factory in Lyon

Precision-Engineered Industrial Control Transformers, Switching Mode Power Supplies & High-Reliability Magnetic Components for Auvergne-Rhône-Alpes Automation.

Direct Factory Catalog

High-Performance Control & Power Conversion Units

Engineered for high instantaneous inrush currents, thermal stability, and rigorous European electrical standards including IEC/EN 61558-2-2.

DC Industrial DIN Rail Power Supply for Automation Cabinets
DIN Rail Unit

DC Industrial DIN Rail Power Supply

Designed for high-vibration control cabinets in industrial automation with over-current and thermal cutoff protection.

View Specification
5V 1A 5W AC DC Switching Power Adapter Class VI CE FCC
Adapter Module

5V 1A 5W AC DC Switching White Power Adapter Wall Plug Class VI 100-240V CE FCC

Compact low-standby power adapter with universal AC input for telemetry and secondary instrument interfaces.

View Specification
AC to DC 12V 24V Dual Slim Thin Switching Power Supply
Slimline SMPS

AC to DC 12V/24V Dual Slim Thin Switching Power Supply for LED Strip and Industrial Use

Low-profile profile enclosure designed to nest inside shallow machinery enclosures and display illumination racks.

View Specification
12V 2000mA Power Adapter 24W Adaptor
Precision Adapter

12V 2000mA Power Adapter 24W Adaptor 5V 6V 9V 12V 24V Power Supply

Multi-voltage regulated adapter platform engineered for low ripple, medical peripherals, and test benches.

View Specification
AC DC Switch Mode Power Supply 12V 24V 48V
Switch Mode Supply

AC DC Switch Mode Power Supply 12V 24V 48V 1A 2A 3A 5A 10A 20A 30A 40A 50A 24vdc Power Supply

High-power modular DC supply for factory automation, robotic drives, and multi-relay distribution networks.

View Specification
Switching Power Supply Enclosure 5W to 1500W
Enclosed SMPS

Switching Power Supply Enclosure 5W 100W 150W 200W 350W 400W 500W 600W 1000W 1500W

Heavy-duty perforated aluminum case with multi-tap terminals, high thermal dissipation, and short-circuit protection.

View Specification
12V 50A 600W Adjustable DC Power Supply
High Current DC

12V 50A 600W Adjustable DC Power Supply AC 110V/220V to 12V Regulated Switching Power Supply

High-amperage bench and industrial cabinet supply with fine voltage trimmer and forced cooling fan control.

View Specification
SMPS 12V 24V 48V LED Driver Power Supply
LED / Solenoid Driver

SMPS 12V 24V 48V 2.5A 5A 8.3A 10A 15A 16.7A 20A 25A 30A AC DC Smps Power Supply 12v150w Led Driver

Ruggedized constant-voltage driver with low EMI footprint, built for signage, optical inspection, and auxiliary circuits.

View Specification
Engineering Whitepaper

Industrial Control Transformers (ICTs): Physics, Design & Application

In modern industrial automation, the Industrial Control Transformer (ICT)—often termed a machine tool transformer—is fundamentally different from general-purpose power distribution units. While standard distribution transformers operate primarily within continuous, steady-state thermal profiles, an industrial control transformer is explicitly engineered to handle high inrush volt-amperes (VA) caused by inductive switching elements such as contactor coils, electromagnetic brakes, solenoids, and pilot actuators without allowing secondary voltage to dip below the dropout threshold of sensitive PLCs and relays.

Critical Sizing Law: According to EN 60204-1 (Safety of Machinery - Electrical Equipment of Machines), control circuits powered by a transformer must maintain at least 85% of nominal secondary voltage during the maximum inrush transient to prevent contactor chatter, micro-welding, and automated cycle tripping.

1. The Inrush VA Problem: Mathematical Modeling

When an AC contactor or solenoid is energized, its magnetic circuit is initially open (the armature has not seated). During this air-gap condition, the coil's inductive reactance is low, and the pull-in current can reach 6 to 10 times the continuous holding current. If the transformer's internal impedance is too high, the resulting internal voltage drop ($I \cdot Z$) causes severe secondary sag.

To accurately calculate the total required VA rating for a control panel, engineers must evaluate both sealed (holding) and inrush conditions using vector summation:

$$\text{Total Inrush VA} = \sqrt{\left(\sum \text{VA}_{\text{sealed}} + \text{VA}_{\text{inrush\_max}}\right)^2 + \left(\sum \text{VA}_{\text{resistive}}\right)^2}$$

Where $\text{VA}_{\text{inrush\_max}}$ represents the largest single inductive inrush event plus the concurrent holding VA of all components already energized. Zelqo Power addresses this by incorporating high-saturation grain-oriented silicon steel (CRGO) laminations and interleaved low-leakage windings, achieving regulation tolerances below 5% at nominal load and remaining above 90% nominal voltage at 300% to 500% inrush overcurrent.

2. Electrical & Thermal Characteristics Matrix

The following performance metrics outline our standard industrial control transformer and low-frequency EI/Toroidal configurations manufactured for European systems:

Parameter Standard Specification Heavy-Duty Industrial / ATEX-Adjacent Standard Compliance
Primary Voltages 230V / 400V ±15V multi-tap (50/60 Hz) 400V / 440V / 480V / 690V IEC 60038 / NF C 15-100
Secondary Voltages 24VAC, 115VAC, 230VAC Dual 12V / 24V / 48V isolated EN 61558-2-2 / EN 60204-1
Insulation Class Class B (130°C) or Class F (155°C) Class H (180°C) Nomex/Kapton barrier UL 1446 / IEC 60085
Dielectric Withstand (Hi-Pot) 3,750 VAC (Primary to Secondary / Earth) 4,200 VAC for 60 seconds (reinforced) EN 61558-1 Clause 18
Leakage Inductance < 1.2% nominal < 0.6% custom interleaved Internal LCR Verification
Regulation Factor 3.5% – 6.0% (at continuous full load) < 2.5% ultra-low regulation Factory Dynamometer Verified

3. Core Geometry: EI Laminations vs. Toroidal Structures

In industrial machine cabinets, the choice between classic laminated EI silicon steel and continuous tape-wound Toroidal cores depends heavily on the layout constraints and electromagnetic sensitivity of adjacent electronics:

EI Transformers: Feature robust stamped silicon steel laminations with welded or bolted brackets. Their rigid mechanical build offers high resistance to physical shocks, simplifies multi-tap terminations, and delivers economical performance in high-power distribution cabinets where electromagnetic interference (EMI) is not the primary limiting factor.

Toroidal Transformers: Utilize an endless grain-oriented magnetic strip without air gaps. This topology slashes no-load excitation losses by up to 80% and reduces the stray magnetic field by up to 90%. In automated systems featuring high-gain analog sensor loops, vision cameras, or medical-grade laboratory enclosures, toroidal control transformers prevent audible magnetostrictive hum and magnetic field pickup in adjacent circuit boards.

4.8 / 5.0
Global B2B Buyer Rating
100%
Hi-Pot & Aging Tested
25+
Winding & Testing Stations
Intertek
On-Site Verified Facility
Localized Applications

Powering Lyon’s High-Tech & Heavy Industrial Hubs

From the chemical facilities of the Rhône valley to advanced precision engineering in Villeurbanne and Saint-Priest, our transformers and SMPS modules meet demanding local operational conditions.

Vallée de la Chimie Chemical Processing (Feyzin / Saint-Fons)

Petrochemical and specialty chemical processing demands extreme electrical isolation and tolerance to harsh industrial environments. Our control transformers feature Class H varnish impregnation, vacuum pressure impregnation (VPI), and tropicalized insulation to resist acidic airborne traces while delivering stable 24V supply to intrinsically safe galvanic barriers and flow control valves.

Automated Logistics & Distribution Hubs (Saint-Quentin-Fallavier)

One of Europe's largest logistics crossroads operates 24/7 automated sorting lines, conveyor systems, and optical parcel scanning gantries. Our heavy-duty switching power supplies and DIN rail transformers absorb line surges caused by rapid cyclic motor braking, ensuring continuous uptime without sensor false-triggers or PLC reboot cycles.

Urban Rail & Transit Infrastructure (SYTRAL / Lyon Tramway & Metro)

Auxiliary substations and signaling wayside cabinets in the Lyon metropolitan transport system require ruggedized, vibration-proof power modules tested to EN 61373 railway standards. Our encapsulated low-frequency toroidal designs operate silently while providing complete physical and galvanic separation between mains lines and signaling logic.

Biopharma & Medical Robotics (Gerland Biodistrict)

High-precision biomanufacturing bioreactors, chromatography units, and robotic surgical assembly in the Gerland district require ultra-low leakage current (<100 µA) and electrostatic shielding between windings to block common-mode noise. Zelqo Power provides custom shielded toroidal transformers that preserve clean analog feedback signals.

Market Dynamics & Standards

Regional Trends Shaping Lyon's Industrial Electrical Procurement

How the Auvergne-Rhône-Alpes industrial renaissance is altering specifications for electrical machine builders and plant engineers.

Strict Compliance with NF C 15-100 & EN 60204-1

French regulatory authorities enforce precise machine safety directives. Machine control circuits must isolate human operators from direct line contact through SELV/PELV configurations, requiring transformers with double or reinforced insulation, tested with 3,750V dielectric isolation barriers to ensure zero touch voltage hazard.

Eco-Design & No-Load Power Losses

Under the European Ecodesign directives, industrial plants in France are actively reducing parasitic standby power consumption. Integrating high-permeability annealed core materials reduces core hysteresis and eddy-current losses, maintaining sub-watt no-load dissipation across thousands of idle factory machines.

Resilient Supply Chains & Custom Small-Batch OEM

With equipment builders facing rigid delivery schedules across the Auvergne-Rhône-Alpes territory, off-the-shelf standard catalog transformers often fail to fit compact modern panels. Direct factory engineering partnerships provide customized footprint dimensions, bespoke dual-voltage primary taps, and fast prototype iterations.

Verified Manufacturing

Shaanxi Zelqo Power Co., Ltd.: Manufacturing Capabilities

Headquartered in Xi'an with certified global distribution, our factory operations have been independently assessed on-site by Intertek to guarantee consistent engineering, safety, and delivery integrity.

100% In-House Winding

Automated multi-axis CNC machines and dedicated circular toroidal winders ensure absolute precision in coil turn ratios, minimal wire stress, and repeatable electrical balance.

Impulse & Surge Testing

Every winding undergoes high-frequency surge testing to detect microscopic inter-turn enamel pinholes and insulation weaknesses before assembly encapsulation.

Full-Load Burn-In

Our switching power supplies and encapsulated transformers complete continuous aging cycles under 100% thermal and electrical load to eliminate infant mortality rates.

Complete Traceability

From raw copper enamel batches and magnetic silicon sheets to final packing cartons, every manufactured component carries a verifiable serial record.

Production Floor & Certified Inspection Stations

Shaanxi Zelqo Power factory production workshop overview
Procurement FAQ

Frequently Asked Questions by Industrial Engineers in Lyon

Detailed technical, compliance, and logistical clarifications for engineering project managers and procurement officers.

How do I size an Industrial Control Transformer (ICT) for Schneider Electric or Siemens contactors?
To properly size an ICT, you must calculate both the continuous holding VA and the maximum instantaneous inrush VA. Gather the technical data sheets for all contactor coils, relays, solenoids, and indicators in the cabinet. Sum the holding VA of all devices energized simultaneously. Identify the single largest inrush VA event (e.g., pulling in a large motor starter or multiple relay banks). The transformer's inrush regulation curve must guarantee that under this total inrush load, secondary voltage remains above 85% (and preferably above 90%) of nominal voltage, in compliance with EN 60204-1. Our engineering department can calculate this directly from your panel's Bill of Materials (BOM).
What certifications are provided for equipment to be installed in France and the EU?
All our industrial transformers and power supplies comply with relevant European Directives, bearing the CE mark. Specifically, our control transformers are built to meet or exceed IEC/EN 61558-1 (General Safety) and IEC/EN 61558-2-2 (Particular Requirements for Control Transformers). For power adapters and SMPS units, designs align with IEC/EN 62368-1 for Audio/Video and ICT equipment safety, alongside RoHS and REACH environmental compliance. Full Type Test reports, dielectric test certificates, and Letters of Conformity are supplied per batch.
Can Zelqo Power accommodate non-standard primary voltages, such as 400V three-phase derived line voltages with taps?
Yes. One of our core manufacturing strengths is custom multi-tap primary winding. Standard European three-phase supplies nominally sit at 400V (phase-to-phase), but industrial networks frequently experience line fluctuations (e.g., 380V, 400V, 415V, 440V). We build transformers with dedicated primary taps (e.g., 230V / 400V / 415V ±15V) to allow field technicians in Lyon to fine-tune the secondary output precisely to 24V or 230V, regardless of local utility voltage variations.
What is the difference between an Isolation Transformer and a Control Transformer?
While all control transformers provide galvanic isolation, a dedicated Control Transformer (per EN 61558-2-2) is specifically engineered with very low internal impedance to minimize voltage drop under instantaneous high-current inductive surges. General-purpose isolation transformers (per EN 61558-2-4) prioritize continuous dielectric isolation and thermal dispersion at rated loads, and often possess higher internal impedance, which causes excessive voltage drops if tasked with pulling in high-VA electromagnetic coils.
What are your lead times and logistics arrangements for Lyon and the Auvergne-Rhône-Alpes region?
For custom prototype transformer designs, our engineering and sample turnaround is typically 7 to 10 working days. Mass production lead times range between 20 and 30 days depending on component volume. We offer complete multimodal logistics to Lyon (Saint-Exupéry Airport for expedited air freight, or ocean freight via Fos-sur-Mer / Le Havre rail links directly to Lyon dry ports). Shipments can be arranged under DAP or DDP terms with all customs clearance handled.
How does Zelqo Power guarantee zero mechanical humming in sensitive environments?
Mechanical transformer hum is caused by magnetostriction within the core laminations. To prevent audible noise in environments such as cleanrooms or acoustic labs, we utilize high-grade, vacuum-annealed magnetic cores, vacuum pressure impregnation (VPI) with specialized solvent-free epoxy resins that fill every microscopic gap between laminations, and offer continuous tape-wound Toroidal architectures which are inherently silent (<30 dB at 1 meter).

Consult Our Magnetics Engineering Team

Submit your electrical specification, circuit schematics, or panel BOM. Our factory engineers will deliver a verified transformer or power supply design with thermal and inrush regulation modeling within 24 hours.